SIEMENS® SOMATOM SENSATION 4 (#118)
(4-PART)

Year of construction: 2003, refurbished by SIEMENS® 2010
Condition: reprocessed by MEDSER
Location: MEDSER showroom, Heusenstamm/Frankfurt
Tube: Dura 532, Akron B

GANTRY

Aperture 70 cm
Scan Field 50 cm, 25 cm
Tilt +/- 30°
Rotational times 0.5, 0.75, 1.0, 1.5 s

DETECTOR

Number of detector rows 8
Elements 5376
Channels per slice 1.344
Number of projections up to 2.320 (1/360°)
Max. slices / rotation 4

IMAGE RECONSTRUCTION

Reconstruction time 1.5 slices/s
Reconstruction slice widths 0.5-10.0 mm
Slice increment 0.1-10 mm
Pitch factor (Volume Pitch) 1-8
Scan length max. 157 cm
Spiral scan time Max. 100 s

TUBE ASSEMBLY

Tube DURA Akron B
Tube current range 28-580 mA
Tube voltages 80, 120, 140 kV
Anode heat storage capacity 5.3 MHU
Focal Spot size according to IEC 60336 0.5 x 0.7 mm/7°
0.8 x 1.2 mm/7°

PATIENT TABLE

Max. table load 200 kg
Table speed 1-150 mm/s
Vertical table travel range 48-102 cm (at table top)
Vertical travel speed 2.5-50 mm/s
Scanable range (metal-free) 157 cm

INSTALLATION

Examination room Temperature range 15-28°” C
Heat dissipation gantry max. 13.5 kW
Surface area for installation 30 m2
Power supply 380-480 V
Nominal line frequency 50; 60 Hz
Max. power connection 60-83 kVA (fuse 100 A)
Power consumption Computer on 4 kVA, 1.1 kW
Power consumption System on standby 7 kVA, 5 kW
Power consumption Scanning 48 kVA

INCLUDED SPECIFICATIONS

2D post processing

  • Image zoom and pan
  • Image manipulations
    • Averaging, subtraction
    • Reversal of gray-scale values
    • Mirroring
  • Advanced image algorithms
    • Low Contrast Enhancement for improving low contrast detectability
    • High Contrast Enhancement for increased sharpness of high contrast structures
    • Advanced Smoothing Algorithm edge preserving and smoothing filter, dedicated to cardiac exams

3D MIP

  • Evaluation of spiral images and display of vessels, vascular anomalies, aneurysms, plaques, and stenosis

CARE tin

  • Achieve the best diagnostic image quality at lowest possible dose, independent of patient size and anatomy.
  • Fully automated dose management for adults and children with up to 68% dose reduction.

Evaluation Tools

  • Parallel evaluation of more than10 Regions of Interest (ROI)
    • Circle
    • Irregular
    • Polygonal
  • Statistical evaluation
    • Area/Volume
    • Standard deviation
    • Mean value
    • Min/max values
    • Histogram
  • Profile cuts
    • Horizontal
    • Vertical
    • Oblique
  • Distance measurement
  • Angle measurement
  • Online measurement of a 5 x 5 pixel size ROI
  • Freely selectable positioning of coordinate system
  • Crosshair
  • Image annotation and labeling

Image Transfer / Networking

Interface for transmitting medical images and information in the DICOM industrial standard. Permits communication between devices from different manufacturers.

  • DICOM Storage (send/receive)
  • DICOM Query/Retrieve
  • DICOM Basic print
  • DICOM Get worklist (HIS/RIS)
  • DICOM MPPS (Modality Performed Procedure Step)
  • DICOM Storage Commitment
  • DICOM Viewer on CD

Real-Time MPR

  • Real-time multiplanar reformatting of secondary views
  • Variable slice thickness (MPR thick, MPR thin) and distance with configurable default values.
  • Viewing perspectives
    • Sagittal
    • Coronal
    • Oblique
    • double oblique
    • freehand (curvilinear)

syngo VRT
Volume Rendering Technique

  • Advanced 3D application package for the optimal display and differentiation of different organs through independent control of color, opacity and shading in up to 4 tissue classes.

SureViewTM

  • Multislice Spiral Image Reconstruction
  • Brilliant image quality and dose savings up to 20% in spiral mode.

UFC – Ultra Fast Ceramic Detector

  • Low patient dose. Up to 30% dose reduction in relation to conventional CT detectors.
  • More power. More or longer spirals due to low mAs requirements for best possible image quality.
  • More speed. Ultra short afterglow. Specially developed for sub-second and multislice applications requiring a higher projection rate.

EXTRA SPECIFICATIONS

  • syngo Osteo CT

    • Non-invasive method for measuring the bone mineral density (BMD) of the vertebrae.
    • Osteo CT measurement is standardized to the ESP Phantom (ESP: European Spine Phantom).
    • Includes table mat and reference phantom for Osteo CT studies.