Siemens® Somatom Emotion 16 (#676)
(16-Zeiler)
Baujahr: 2009
Zustand: wiederaufbereitet durch MEDSER
Standort: MEDSER Showroom, Heusenstamm/Frankfurt
Röhre: Dura 422 MV
Gantry
Aperture | 70 cm |
Scan Field | 50 cm |
Tilt | +/- 30° |
Rotational times | 0.6, 1.0, 1.5 s |
Detector
Number of detector rows | 16 |
Elements | 17.664 |
Channels per slice | 1472 |
Number of projections | Up to 1.250 (1/360°) |
Max. slices / rotation | 16 |
Image Reconstruction
Reconstruction time | up to 8 images/s |
Reconstruction slice widths | 0.6, 0.75, 1.0, 1.5, 2.0, 3.0, 4.0, 5.0, 6.0, 8.0,10.0 mm |
Slice increment | 0.1–10 mm |
Pitch factor (Volume Pitch) | 0.4–1.8 |
Spiral scan time | max. 100 s |
Scan length | max. 150 cm |
Tube Assembly
Tube | DURA 422MV |
Tube current range | 20–345 mA |
Tube voltages | 80, 110, 130 kV |
Anode heat storage capacity | 5.0 MHU |
Focal Spot size according to IEC 60336 | 0.8 x 0.5 mm/7° 0.8 x 0.7 mm/7° |
Patient Table
Max. table load | 200 kg |
Table speed | 1–100 mm/s |
Vertical table travel range | 45–83 cm (at table top) |
Vertical travel speed | <22,4 mm/s |
Scanable range (metal-free) | 153 cm |
Installation
Examination room Temperature range | 18–30° C |
Heat dissipation gantry | max. 6.8 kW |
Surface area for installation | 18 m2 |
Power supply | 380–480 V |
Nominal line frequency | 50; 60 Hz |
Max. power connection | <70 kVA |
Power consumption System on standby | <3,7 kW |
Power consumption scanning | <7,0 kW |
Included Specifications
2D post processing
- Image zoom and pan
- Image manipulations
- Averaging, subtraction
- Reversal of gray-scale values
- Mirroring
- Advanced image algorithms
- Low Contrast Enhancement for improving low contrast detectability
- High Contrast Enhancement for increased sharpness of high contrast structures
- Advanced Smoothing Algorithm edge preserving and smoothing filter, dedicated to cardiac exams
CARE Bolus CT
- Scan mode for contrast bolus triggered data acquisition.
- Significant improvement of the planning procedure and diagnosis by enabling an optimum spiral scan start after contrast injection.
- The procedure is based on repetitive low-dose monitoring scans at one slice level and analysis of the time density curve in a region-of-interest (ROI).
CARE Dose
- Automated real-time tube current adjustment for best diagnostic image quality at lowest possible dose, independent of patient size and anatomy
- Fully automated dose management for adults and children with up to 68% dose reduction
CARE Filter
Specially designed X-ray exposure filter installed at the tube collimator. Up to 25% dose reduction with increased image quality.
CARE Topo
- Real-time topogram
- Manual interruption possible once desired anatomy has been imaged
CINE Display
- Display of image sequences
- Automatic or interactive with mouse control
- Max. image rate >10 frames/s
CT-Angiography
- MIP: Maximum Intensity Projection
- MinIP function for projection within a small slab to focus on particular vascular structure
Evaluation of spiral images and display of vessels, vascular anomalies, aneurysms, plaques, and stenosis
Evaluation Tools
- Parallel evaluation of more than10 Regions of Interest (ROI)
- Circle
- Irregular
- Polygonal
- Statistical evaluation
- Area/Volume
- Standard deviation
- Mean value
- Min/max values
- Histogram
- Profile cuts
- Horizontal
- Vertical
- Oblique
- Distance measurement
- Angle measurement
- Online measurement of a 5 x 5 pixel size ROI
- Freely selectable positioning of coordinate system
- Crosshair
- Image annotation and labeling
Image Transfer / Networking
- Interface for transmitting medical images and information in the
DICOM industrial standard. Permits communication between devices from different manufacturers. - DICOM Storage (send/receive)
- DICOM Query/Retrieve
- DICOM Basic print
- DICOM Get worklist (HIS/RIS)
- DICOM MPPS (Modality Performed Procedure Step)
- DICOM Storage Commitment
- DICOM Viewer on CD
Pediatric protocols
- Special clinical protocols with 80 or 110 kV selection and a wide range of mAs settings. The X-ray exposure is adapted to the child’s (and small adults) weight and age, substantially reducing the effective patient dose.
SureViewTM
- Multislice Spiral Image Reconstruction
- Brilliant image quality and dose savings up to 20% in spiral mode.
syngo 3D SSD
(Surface Shaded Display)
- Three-dimensional display of surfaces with different density values
- Soft tissue
- Bone
- Contrast-enhanced vessels
syngo Dynamic Evaluation
- Evaluation of contrast enhancement in organs and tissues
- Calculation of
- Time-density curves (up to 5 ROI’s)
- Peak-enhancement images
- Time-to-peak images
UFC – Ultra Fast Ceramic Detector
- Low patient dose. Up to 30% dose reduction in relation to conventional CT detectors.
- More power. More or longer spirals due to low mAs requirements for best possible image quality.
- More speed. Ultra short afterglow. Specially developed for sub-second and multislice applications requiring a higher projection rate.
Extra Specifications
- 3D advanced editor
- 3D Boneremoval
- 3D Flymode
- 3D interactive minimum intensity projection
- 3D multiplanar reformatting
- 3D shaded surface display
- 3D volume editor
- 3D Volume Rendering
- Biopsy
- Bolus-Track
- CARE Dose Modulation
- CARE Vision
- Dicom modality performed procedure step
- DICOM SR-Viewer
- Dicom Worklist
- MR-Support-i
- Recon Plus
- RTD
- Volume Workflow