Low Contrast Enhancement for improving low contrast detectability
High Contrast Enhancement for increased sharpness of high contrast structures
Advanced Smoothing Algorithm edge preserving and smoothing filter, dedicated to cardiac exams
CARE Dose4D
Achieve the best diagnostic image quality at lowest possible dose, independent of patient size and anatomy.
Fully automated dose management for adults and children with up to 68% dose reduction.
CARE Filter
Specially designed X-ray exposure filter installed at the tube collimator. Up to 25% dose reduction with increased image quality.
CINE Display
Display of image sequences
Interactively with mouse controlled rate or automatically
Max. image rate >10/s
CT-Angiography
MIP: Maximum Intensity Projection
MinIP function for projection within a small slab to focus on particular vascular structure
Evaluation of spiral images and display of vessels, vascular anomalies, aneurysms, plaques, and stenosis
Dynamic Evaluation
Evaluation of contrast enhancement in organs and tissues
Calculation of
Time-density curves (up to 5 ROI’s)
Peak-enhancement images
Time-to-peak images
Evaluation Tools
Parallel evaluation of more than10 Regions of Interest (ROI)
Circle
Irregular
Polygonal
Statistical evaluation
Area/Volume
Standard deviation
Mean value
Min/max values
Histogram
Profile cuts
Horizontal
Vertical
Oblique
Distance measurement
Angle measurement
Online measurement of a 5 x 5 pixel size ROI
Freely selectable positioning of coordinate system
Crosshair
Image annotation and labeling
Image Transfer / Networking
Interface for transmitting medical images and information in the DICOM industrial standard. Permits communication between devices from different manufacturers.
DICOM Storage (send/receive)
DICOM Query/Retrieve
DICOM Basic print
DICOM Get worklist (HIS/RIS)
DICOM MPPS (Modality Performed Procedure Step)
DICOM Storage Commitment
DICOM Viewer on CD
Pediatric protocols
Special clinical protocols with 80 or 110 kV selection and a wide range of mAs settings. The X-ray exposure is adapted to the child’s (and small adults) weight and age, substantially reducing the effective patient dose.
Real-Time MPR
Real-time multiplanar reformatting of secondary views
Variable slice thickness (MPR thick, MPR thin) and distance with configurable default values.
Viewing perspectives
Sagittal
Coronal
Oblique
double oblique
freehand (curvilinear)
SureView
Multislice Spiral Image Reconstruction
Brilliant image quality and dose savings up to 20% in spiral mode.
syngo 3D SSD Surface Shaded Display
Three-dimensional display of surfaces with different density values
Soft tissue
Bone
Contrast-enhanced vessels
UFC – Ultra Fast Ceramic Detector
Low patient dose. Up to 30% dose reduction in relation to conventional CT detectors.
More power. More or longer spirals due to low mAs requirements for best possible image quality.
More speed. Ultra short afterglow. Specially developed for sub-second and multislice applications requiring a higher projection rate.