Low Contrast Enhancement for improving low contrast detectability
High Contrast Enhancement for increased sharpness of high contrast structures
Advanced Smoothing Algorithm edge preserving and smoothing filter, dedicated to cardiac exams
CARE Bolus CT
Scan mode for contrast bolus triggered data acquisition.
Significant improvement of the planning procedure and diagnosis by enabling an optimum spiral scan start after contrast injection.
The procedure is based on repetitive low-dose monitoring scans at one slice level and analysis of the time density curve in a region-of-interest (ROI).
CARE Dose
Automated real-time tube current adjustment for best diagnostic image quality at lowest possible dose, independent of patient size and anatomy
Fully automated dose management for adults and children with up to 68% dose reduction
CARE Filter
Specially designed X-ray exposure filter installed at the tube collimator. Up to 25% dose reduction with increased image quality.
CARE Topo
Real-time topogram
Manual interruption possible once desired anatomy has been imaged
CINE Display
Display of image sequences
Automatic or interactive with mouse control
Max. image rate >10 frames/s
CT-Angiography
MIP: Maximum Intensity Projection
MinIP function for projection within a small slab to focus on particular vascular structure
Evaluation of spiral images and display of vessels, vascular anomalies, aneurysms, plaques, and stenosis
Evaluation Tools
Parallel evaluation of more than10 Regions of Interest (ROI)
Circle
Irregular
Polygonal
Statistical evaluation
Area/Volume
Standard deviation
Mean value
Min/max values
Histogram
Profile cuts
Horizontal
Vertical
Oblique
Distance measurement
Angle measurement
Online measurement of a 5 x 5 pixel size ROI
Freely selectable positioning of coordinate system
Crosshair
Image annotation and labeling
Image Transfer / Networking
Interface for transmitting medical images and information in the DICOM industrial standard. Permits communication between devices from different manufacturers.
DICOM Storage (send/receive)
DICOM Query/Retrieve
DICOM Basic print
DICOM Get worklist (HIS/RIS)
DICOM MPPS (Modality Performed Procedure Step)
DICOM Storage Commitment
DICOM Viewer on CD
Pediatric protocols
Special clinical protocols with 80 or 110 kV selection and a wide range of mAs settings. The X-ray exposure is adapted to the child’s (and small adults) weight and age, substantially reducing the effective patient dose.
SureViewTM
Multislice Spiral Image Reconstruction
Brilliant image quality and dose savings up to 20% in spiral mode.
syngo 3D SSD (Surface Shaded Display)
Three-dimensional display of surfaces with different density values
Soft tissue
Bone
Contrast-enhanced vessels
syngo Dynamic Evaluation
Evaluation of contrast enhancement in organs and tissues
Calculation of
Time-density curves (up to 5 ROI’s)
Peak-enhancement images
Time-to-peak images
UFC – Ultra Fast Ceramic Detector
Low patient dose. Up to 30% dose reduction in relation to conventional CT detectors.
More power. More or longer spirals due to low mAs requirements for best possible image quality.
More speed. Ultra short afterglow. Specially developed for sub-second and multislice applications requiring a higher projection rate.
Extra Specifications
Real-Time MPR
Real-time multiplanar reformatting of secondary views
Variable slice thickness (MPR thick, MPR thin) and distance with configurable default values.
Viewing perspectives
Sagittal
Coronal
Oblique
double oblique
freehand (curvilinear)
RTP Enhancement
Hardware and software components to optimize the RTP process
syngo CT Oncology
Fast-track routine diagnostic oncology, staging, and follow-up. It provides a range of fully automated tools specifically designed to support physicians in the detection, segmentation, and evaluation of suspicious lesions including dedicated tools for lung, liver, and lymph node assessment. It also offers a fully automated follow-up protocol and features LungCAD (Computer Assisted Detection). syngo CT Oncology also facilitates functional imaging offering fusion of PET with CT data.
syngo Dental CT
Reformatting of panoramic slices and paraxial sections through the lower and upper jaw for analysis in connection with implantation surgery
syngo InSpace4D
One-click bone removal
One-click table removal
Automated segmentation and removal of bony structures for vascular analysis
4D evaluation of the beating heart with full resolution
Real-time navigation through moving anatomy in user selectable arbitrary planes
High performance volume reading for physician’s diagnosis and pre-surgical planning in daily clinical routine
syngo LungCARE CTa
Software for fast 3D-based visualization and quantitative evaluation of lung nodules, with lowest possible radiation dose. Includes fully automated follow-up.
syngo Osteo CT
Non-invasive measurement of the bone mineral density of the lumbar spine to help early diagnosis of osteopenia and osteoporosis, and to assess the effectiveness of treatment
Osteo CT measurements are standardized to the ESP Phantom (ESP: European Spine Phantom)
Includes table mat and reference Phantom for Osteo CT studies
WorkStream4D
4D workflow with direct generation of axial, sagittal, coronal, or double-oblique images from standard scanning protocols
Elimination of manual reconstruction steps
Reduction of data volume up to a factor of 10, since virtually all diagnostic information is captured in 3D slices